Skip to content

Failed

gpkit.tests.from_paths.TestFiles.test_gassolar_solar_solar_py_mosek_cli (from gpkit.tests.from_paths.TestFiles-20200806045922)

Failing for the past 1 build (Since Failed #455 )
Took 2 sec.

Error Message

None

Stacktrace

Traceback (most recent call last):
  File "/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/gpkit/tests/helpers.py", line 55, in test
    testfn(name, import_dict, path)(self)
  File "/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/gpkit/tests/from_paths.py", line 48, in <lambda>
    lambda self: getattr(self, name)()))  # pylint:disable=undefined-variable
  File "/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/gpkit/tests/from_paths.py", line 37, in test_fn
    mod.test()
  File "/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/gassolar/gassolar/solar/solar.py", line 368, in test
    m.solve()
  File "/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/gpkit/constraints/prog_factories.py", line 105, in solvefn
    result = progsolve(solver, verbosity=verbosity, **solveargs)
  File "/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/gpkit/constraints/gp.py", line 231, in solve
    verbosity=verbosity-2)
  File "/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/gpkit/constraints/gp.py", line 252, in generate_result
    result = self._compile_result(solver_out)  # NOTE: SIDE EFFECTS
  File "/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/gpkit/constraints/gp.py", line 342, in _compile_result
    dlogv_dlogc = dv_dc * result["constants"][c]/val
  File "/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/gpkit/keydict.py", line 174, in __getitem__
    raise KeyError(key)
KeyError
		

Standard Output

Using solver 'mosek_cli'
 for 592 free variables
  in 918 posynomial inequalities.
Solving took 0.24 seconds.
Using solver 'mosek_conif'
 for 592 free variables
  in 918 posynomial inequalities.
Solving took 0.283 seconds.
Using solver 'mosek_cli'
 for 1250 free variables
  in 1872 posynomial inequalities.
Solving took 0.409 seconds.
Using solver 'mosek_conif'
 for 1250 free variables
  in 1872 posynomial inequalities.
Solving took 0.533 seconds.
	

Standard Error

/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/venv2_gpkit/lib/python3.5/site-packages/pint/quantity.py:1377: UnitStrippedWarning: The unit of the quantity is stripped.
  warnings.warn("The unit of the quantity is stripped.", UnitStrippedWarning)
/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/venv2_gpkit/lib/python3.5/site-packages/pint/quantity.py:1377: UnitStrippedWarning: The unit of the quantity is stripped.
  warnings.warn("The unit of the quantity is stripped.", UnitStrippedWarning)
/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/venv2_gpkit/lib/python3.5/site-packages/pint/quantity.py:1377: UnitStrippedWarning: The unit of the quantity is stripped.
  warnings.warn("The unit of the quantity is stripped.", UnitStrippedWarning)
/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/venv2_gpkit/lib/python3.5/site-packages/pint/quantity.py:1377: UnitStrippedWarning: The unit of the quantity is stripped.
  warnings.warn("The unit of the quantity is stripped.", UnitStrippedWarning)
/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/venv2_gpkit/lib/python3.5/site-packages/gassolar/environment/solar_irradiance.py:40: RuntimeWarning: overflow encountered in exp
  tau = np.exp(-0.175/costhsun)
/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/venv2_gpkit/lib/python3.5/site-packages/pint/quantity.py:1377: UnitStrippedWarning: The unit of the quantity is stripped.
  warnings.warn("The unit of the quantity is stripped.", UnitStrippedWarning)
/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/venv2_gpkit/lib/python3.5/site-packages/gassolar/environment/solar_irradiance.py:40: RuntimeWarning: overflow encountered in exp
  tau = np.exp(-0.175/costhsun)
/jenkins/workspace/CE_gpkit_PR_research_models/buildnode/reynolds/optimizer/mosek/venv2_gpkit/lib/python3.5/site-packages/pint/quantity.py:1377: UnitStrippedWarning: The unit of the quantity is stripped.
  warnings.warn("The unit of the quantity is stripped.", UnitStrippedWarning)